Bradford University IPI Building - 2003
Smoke + Natural Ventilation System

Multi-purpose Smoke and Natural Ventilation System for Atrium. 24volt Linear Actuators and Smoke Ventilation Control Panel with a fire alarm interface with BMS interface for daily ventilation. Rain Sensor override incorporated.
Manchester Piccadilly Railway Station - 2003
Smoke + Natural Ventilation System

The Queen opened the new £55million Railway Concourse, with 7 no. ETFE 3.5m x 3.5m massive roof vents opening 1000mm. These new BSY controlling rack & pinion actuators were linked with specially designed locking actuators to provide the necessary pressure force when closed. Control was provided by a smoke ventilation panel with weather sensors for natural ventilation.
Capital West Apartments, Brentford, Barratt (West London) - 2002/03
Smoke Ventilation System

Multi-phased Apartment Blocks with Stair and Lobby Smoke Ventilation System - worked closely with Emanuel Smith Partnership Service Engineers. 105 no. Single & Twin Chain 24volt Chain Actuators. Multi-zone Smoke Ventilation Control Panels with remote status indication for each vent.

Wolverhampton University MC Block - 2002
Smoke + Natural + Manual Ventilation Systems

After liaison with RMJM Architects, we provided a showcase for the full spectrum of products and services that Dyer can offer! Over 250 BMS-controlled, concealed chain actuators for natural ventilation in the classrooms. Over 1000mm stroke actuators and door drives provided for smoke ventilation. To finish, the laboratories were provided with manual Teleflex remote winding gear.

Blyth Community College, Northumberland - 2002
Smoke + Natural Ventilation System

Various Smoke & Natural Ventilation Systems designed in close co-operation with White Young Green Consultants, incorporating a full service and maintenance contract. Included 24volt chain actuators and control panels providing smoke ventilation via a fire alarm interface. Also provided 230volt chain actuators and switches to classrooms. All the actuators (over 100 no.) were to specific RAL colours.

Telford College of Arts & Technology - 2002
Natural & Manual Ventilation Systems

230volt electrical chain actuators are operated from key switches for staff use. In addition, we installed manual Teleflex Remote Winding Gear, specially coloured to suit the dark aluminium profile.

Seaham Hall Hotel, County Durham - 2001
Smoke + Natural Ventilation System

This high-tech hotel features all the latest features for the pampered customer. The atrium now has a similarly ultra-modern ventilation system. This incorporates a stand-alone natural ventilation system with incremental opening upon temperature change with a weather station override. The fire alarm link allows for smoke ventilation of the whole atrium.


Page <<1<<2<<3    4


Dyer Environmental Controls Limited - Registered Office Address: Unit 10 Lawnhurst Trading Estate - Cheadle Heath - Stockport - SK3 0SD
Tel: +44 (0)161 491 4840 | Fax: +44 (0) 161 491 4841 | email:enquiry@dyerenvironmental.com
Registered in England No. 02670985 VAT Registration No. 611 3292 79
Directors; D W Walker, N H Walker OBE FCMA, J Crossley B Eng