Harper Adams University, Shropshire - Learning Resource Centre - 2004
Natural Ventilation System

State-of-art Building Natural Ventilation System designed in conjunction with Ventilation Analytical Specialists from DeMontford University. 140 no. RAL coloured chain actuators for the windows and rooflights and linear drive actuators for the internal louver system. 12 no. Multi-zone Natural Ventilation Control Panels complete with BMS incremental opening and position indication. All working in conjunction with mini-atrium extract ventilation systems.
Broughton Park Rugby Clubhouse - 2004
Manual System

Teleflex Manual Remote Winding Mechanisms were required for the high level ventilation of the main hall. Each mechanism set operates 2 no. top hung windows.
Kingsdale School, London - 2003-04
Smoke + Natural Ventilation System

Dyer provided externally mounted linear actuators to open huge ETFE 12metre x 2metre wide pitched roof vents by over 1200mm! The unique BSY technology allowed 6 no. actuators to be fully synchronised on each vent, providing incremental control. A BMS system was also provided, with thermostat space sensors, CO2 sensors, weather station, and powered low-level air intake louvres, with control to the ETFE roof for inflation and deflation of the air cushions.

D+H Mechatronic Award Winners - 2003
Dyer has beaten off stiff competition from over 50 other international distributors to be presented the D+H Mechatronic International Distributor of the Year Award in Austria. Summing up what has been a particularly memorable year for Dyer, Sales Manager Jon Crossley said: "This year has seen us putting together some very exciting projects for different companies. We shall build upon our achievements to make 2004 even more successful."

OCDEM Building, Oxford Radcliffe Hospital - 2003
Smoke + Natural Ventilation System

We believe we have provided the actuators to open the world's biggest opening smoke vent! The ETFE vent is 22.5m wide by 1.5m high, which we provided 8 no. 800mm synchronized linear actuators. These revolutionary BSY actuators provide constant communication between each other, utilising microprocessors housed within each motor. This design provides a constant opening speed and force throughout the entire length of the vent.


Company News. Page <<1<<2   3   4>>


Dyer Environmental Controls Limited - Registered Office Address: Unit 10 Lawnhurst Trading Estate - Cheadle Heath - Stockport - SK3 0SD
Tel: +44 (0)161 491 4840 | Fax: +44 (0) 161 491 4841 | email:enquiry@dyerenvironmental.com
Registered in England No. 02670985 VAT Registration No. 611 3292 79
Directors; D W Walker, N H Walker OBE FCMA, J Crossley B Eng